Pin16

P0144

O2 Sensor Circuit High Voltage (Bank 1 Sensor 3)

Severity
Low
Driving
Drivable — book it in

Oxygen sensor 3 on bank 1, downstream of the catalytic converter, is reporting persistently high voltage - a rich signal. As a monitoring sensor rather than a control sensor, this rarely changes how the car drives.

Possible causes

What you might notice

What to check, in order

  1. Check for upstream fuel or misfire codes first - a genuinely rich mixture will show up here too.
  2. Inspect the wiring for damage that could short the signal to power.
  3. Check the connector for water and corrosion.
  4. Replace the sensor once wiring and upstream mixture faults are ruled out.

Read this code from your own car

Plug an ELM327 adapter into the OBD-II port under the dashboard. Pin16 reads every stored, pending and permanent code, explains each one like this page does — offline, with no account — and shows what the car recorded when the fault was set.

Get Pin16 on Google Play

Where this code sits