Fan Power/Ground Circuit

Severity
High
Driving
Drivable — book it in

A fault in the cooling fan's power or earth circuit. Fans draw a large current, so their supply and earth connections carry more than most - and corrosion or a loose connection there produces heat, voltage drop and a fan that turns slowly or not at all.

Possible causes

What you might notice

What to check, in order

  1. Perform a voltage drop test on the fan supply and earth while the fan is running. High resistance in a corroded connection makes the fan turn slowly while everything tests as connected.
  2. Inspect the fan earth point for corrosion and clean it.
  3. Look for heat discolouration at the connector, which indicates a poor connection that has been running hot.
  4. Watch the temperature gauge in slow traffic and stop if it climbs. A fan fault shows itself when the car is stationary and clears at speed, because airflow through the radiator does the fan's job - that pattern is the clearest evidence available and costs nothing to observe.
  5. Check whether the fan runs at all when the engine is hot or the air conditioning is on.
  6. Check the fuse and swap the relay with an identical one from elsewhere in the box.
  7. Inspect the connector and the fan earth for corrosion.
  8. Check for debris in the fan and that it spins freely with the engine off and cool.