Pin16

P2514

Event Data Recorder Request Circuit High

Severity
Low
Driving
Drivable — book it in

The event data recorder request circuit is reading high - typically shorted to voltage or a lost earth. The request signal cannot be passed reliably, so an event may not be recorded.

Possible causes

What you might notice

What to check, in order

  1. Disconnect at one end and check whether the high reading persists, to establish which side of the circuit is at fault.
  2. Read the restraints module as well. The recorder is usually triggered from there, and a restraints fault matters far more than this code does.
  3. Inspect the connectors at both modules.
  4. Check the wiring for chafe damage.
  5. If an airbag warning light is on, treat the restraints side as the priority and do not work on restraints wiring with the battery connected.

Read this code from your own car

Plug an ELM327 adapter into the OBD-II port under the dashboard. Pin16 reads every stored, pending and permanent code, explains each one like this page does — offline, with no account — and shows what the car recorded when the fault was set.

Get Pin16 on Google Play

Where this code sits